Accessories; Connecting To The Tgs; Tgs Adapted Machines; Tgs Non-Adapted Machines - Technogym Bikerace Service Maintenance Manual

Table of Contents

Advertisement

BIKERACE: Service & Maintenance Manual - rev. 1.1

4. ACCESSORIES

4.1. CONNECTING TO THE TGS

The machine can be connected to the Technogym System by installing a special upgrade kit, which
involves the following:
• Installation of a special SW;
• Installation of special cables, for providing – through a 9-pin D-connector at the back of the
display – the half duplex RS 485 serial port for connecting to the TGS reader.
The CPU board is connected to the serial connector via the cable described below, which is supplied
together with the upgrade kit.
4.1.1.
TGS
ADAPTED MACHINES
TGS adapted machines can be connected to the TGS reader using the RS 485 serial port of the CPU
board in half duplex mode. Install the special cable illustrated below to make this serial port
available on a 9-pin D connector at the back of the display.
CPU board
CN2
1
3
7
8
4.1.2.
TGS
NON
TGS non-adapted machines can be connected to the TGS reader using the full-duplex mode RS 485
serial port of the CPU board, available on the serial ports panel. Install the special kit – consisting of
a cable and a full-to-half duplex 485 serial protocol converter – to make available the half duplex
RS 485 port for the TGS reader on a 9-pin D connector at the back of the display.
In both cases, the TGS reader is of type 485.
For further information, including troubleshooting, refer to the manual "Technogym System:
Installation Manual".
TGSRN2RACE: Internal cable
Retrofit support flange – CPU board
Signal
+12 Vdc
ground
-Serial
+Serial
-
ADAPTED MACHINES
Color
DB9 male
Yellow
1
Green
5
Brown
3
White
2
Page 4.1