6.4.5 Status Code Help

This screen is view only. No password is required. The information
displayed is useful in determining the status of the monitor. The screen
contains the five-digit STATUS word and a decoded list of the individual
status conditions. To view this screen select STATUS CODE HELP from
the MAIN MENU by using the arrow keys and press ENTER. Choose the
TIE/Path you want to view with the arrow keys, and press ENTER. This
will bring up the PRIMARY/EXTENDED STATUS selection screen.
Make a selection with the arrow keys and press ENTER. This brings up
the STATUS CODE HELP screen. It has two pages. Switch from page
one to page two with the "Page Up/Page Down" keys. Press the ESC key
to leave the screen. The individual codes are additive. If a SPAN HIGH-
CAL BAD and SPAN LOW-CAL BAD are active at the same time the
STATUS WORD would be "6000".
STATUS CODE HELP
TIE 1 Path A
Choose TIE / Path
TIE 1 Path A
TIE 1 Path B
TIE 1 Path AB
TIE 2 Path A
TIE 2 Path B
TIE 1 Path B
TIE 2 Path AB
Note: There are too many potential status codes to combine into one six-digit
octal number. The EXTENDED STATUS is simply a second six-digit
octal number to handle the additional status.

6.4.6 Output Cal Tests

This is a password protected change screen. It allows you to command the
system into different modes of operation. When the screen comes up, the
COMMAND MODE line will be highlighted. Scroll through the modes
SECTION 6.0, ENHANCED REMOTE PANEL W/MULTI I/O MODULE
Figure 6-4
Choose
Primary / Secondary
Status
Primar
Extended
TIE 1 Path AB
TIE 2 Path A
TIE 2 Path B
TIE 2 Path AB
Page #1
PRIMARY STATUS CODES
00001
Purge Failure Dn Stream
00002
Purge Failure Up Stream
00004
Out Of Service
00010
FPGA Config Fault
00020
Temp Out Of Range
00040
Min Signal Energy DnSt
00100
Min Signal Energy UpSt
00200
Span High Offset TD Cal
CURRENT STATUS : XXXXX
EXTENDED STATUS CODES
00001
Divide By Zero
00002
FPGA Timeout
00004
3 X FPGA Timeout
00010
Filter Mismatch
00020
BoxCar Overflow
00040
Gain Disabled
00100
Noise Thresh Disabled
00200
Yet To Be Defined
CURRENT STATUS : XXXXX
Page up / Page Down
Page #2
PRIMARY STATUS CODES
00400
Span Low Offset TD Cal
01000
Zero Calib Bad
02000
Span High Calib Bad
04000
Span Low Calib Bad
10000
S/N Ratio Warn DnStream
20000
S/N Ratio Warn UpStream
40000
Signal Energy Ratio >3X
100000 Yet To Be Defined
CURRENT STATUS : XXXXX
EXTENDED STATUS CODES
00400
Yet To Be Defined
01000
Yet To Be Defined
02000
Yet To Be Defined
04000
Yet To Be Defined
10000
Yet To Be Defined
20000
Yet To Be Defined
40000
Yet To Be Defined
100000 Yet To Be Defined
CURRENT STATUS : XXXXX