Troubleshooting - Casio PX-780 Service Manual

Handheld terminal
Table of Contents

Advertisement

4. TROUBLESHOOTING

4-1. Does not turn ON
Check the voltage and
placement of the battery.
NG
4-2. Memory error occurs after booting IT-3100.
Memory error may occur when IT-3100 with an empty backup battery is booted.
In this case, initialize the memory as indicated on the display.
4-3. The diagnostic program cannot be loaded.
Refer to "4-12. PCMCIA NG".
4-4. SDRAM NG
Replace the MAIN PCB and check again.
4-5. NAND-FROM NG
Replace the MAIN PCB and check again.
Check if LCD
OK
connector and BL connector
are correctly inserted.
NG
Check on the
detection SW.
NG
– 14 –
OK
MAIN PCB is
defective.
LCD connector and
BL connector are
not correctly
inserted.
OK
Battery is defective or
incorrectly inserted.
Detection SW is
defective.
Replace the
MAIN PCB and
check again.
Continue check.
Replace the
Detection SW and
check again.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

It-3100 series

Table of Contents