Technical data

14.1

General specifications

14.1
General technical data
Order number
Dimensions
Weight
Supply voltage (U
Line voltage frequency
Transient voltage interruption
Power consumption (at 210 W secondary
power)
Current output (AC)
Noise emission
Degree of protection
Safety
Protection class
Safety regulations
Electro-magnetic compatibility (EMV)
Emitted interference (AC)
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
Immunity to discharges of static electricity
SIMATIC Rack PC 840 V2
Operating Instructions, Edition 05/2006, A5E00248055-04
)
N
6ES7643-7... (for details, refer to the ordering
documentation)
430.4x177.4x444.4 (WxHxD in mm). Detailed
dimensional specifications are found in the
"Dimensional drawings" section.
min. 16 kg, max. 23 kg
100-127 V or 200-240 V (85-135 V or 180-264 V)
autorange
50 – 60 Hz
min. 20 ms (at 93 / 187 V AC)
(max. 10 events per hour; recovery time min 1 s)
320 W (efficiency approx. 65%)
+5 V/30 A +3.3 V/28 A
permitted accumulated power is 180 W
+12 V/15 A -12 V/0.8 A –5 V/0.3 A +5 Vaux/2 A
Max. accumulated power of all voltages is 210 W
< 55 dB(A) to DIN 45635
IP 41 front, IP 20 rear
Protection class I according to IEC 61140
EN 60950-1, UL60950-1, CSA C22.2 No 60950-00
EN 55022 Class A, FCC class A
EN 61000-3-2 Class D, EN 61000-3-3
± 2 kV, (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge symm)
± 2 kV; (according to IEC 61000-4-5; Surge asymm)
± 1 kV;(to IEC 61000-4-4; Burst; length < 10 m)
± 2 kV; (to IEC 61000-4-4; Burst; length > 30 m)
± 2 kV; (to IEC 61000-4-5:1995; length > 30 m)
± 6 kV contact discharge; (according to IEC 61000-4-2)
± 8 kV air discharge; (according to IEC 61000-4-2)