3.4
Function
3.4
• Integrated and configurable monitoring functions (program execution (watchdog), internal
• Enhanced diagnostic / messaging via Ethernet, E-mail, SMS, and for direct input in
• RAID1 for automatic data mirroring on two hard disks
3.5
Features
3.5
General features
Design
Enclosure
Drive bays
Slots for expansion cards
Video
Interfaces
PROFIBUS/MPI (12 Mbps)
SIMATIC Rack PC 840 V2
Operating Instructions, Edition 05/2006, A5E00248055-04
enclosure temperature, fan speed)
SIMATIC software via OPC (optional via SIMATIC PC DiagMonitor):
– Operating hours counter
– Hard disk status
– System status (heartbeat)
– Automatic logging of all messages by means of log file
– Options of central monitoring of networked SIMATIC PCs
19" rack, 4 HE
•
Robust installation enclosure, all metal
•
Prepared for mounting telescopic rails
•
Horizontal installation is possible
•
Lockable front cover as access protection
•
Dust protection by means of overpressure ventilation
•
using bearing seated front fan through filter
Case cover can be opened and front fan can be
•
replaced without special tools
Card retainer for reliable operation of PC modules under
•
vibration and shock conditions
Front: 3 x 5.25" and 2 x 3.5"
•
Internal: 2 x 3.5" (in the optional vibration-damping drive
•
bracket)
5x PCI long
•
2x PCI/ISA (shared) long
•
3x ISA long
•
max. 10 modules simultaneously
Pro Savage 8 AGP 4x
8 to 32 MB used in RAM
CRT:
-up to 1280x1024 at 100 Hz / 32-bit color resolution
-up to 1600 x1200 at 60 Hz / 16-bit color resolution
12 Mbps (isolated potential, compatible to CP 5611);
optional
Description
3.4 Function
3-3