iSERIES 100 /200 /300 /400
Causes & troubleshooting:
• As this is just a continuity test it is very unlikely to be a bad inverter. Most likely a poor connection or
defective ribbon cable.
o Check ribbon cable connections at both ends of INV1A to CCM J31 (1A) cable. Make sure it is plugged
into J31, the top connector, on the CCM.
o Plug a different inverter cable into J31, doesn't matter which one for this test as long as it's plugged
into an inverter on the other end. If still gives 224, "Inverter 1 not found" fault, it's a bad CCM. Oth-
erwise it's the ribbon cable.
225-230 Inverter Revision and CCM incompatible.
If sometime in the future we should make a change to the inverter making it incompatible with older CCM we
have included a hardware key that would change to indicate this. During the power up sequence, before power
is connected to the inverters, the CCM does a continuity test to determine what is the hardware key configura-
tion. The key uses 3 lines of the CCM to inverter ribbon cable which are named IS_ID_A, IS_ID_B, IS_ID_C (on
pins 12, 13 & 14) and checks for continuity to a 4th line OUTCOM (pin 9). The test consists of applying voltage
to OUTCOM and looking for that voltage coming back on the 3 ID pins. The present configuration has all 3
lines connected to OUTCOM so all 3 should be high.
To get the 225-230 code now when we don't have any incompatible revisions would most likely be a bad con-
nection in the ribbon cable between the CCM and the inverter or a defective CCM (unlikely).
• On the inverter section swap the ribbon cable with that of a different inverter section. If fault remains
unchanged, still calls out the original inverter section, the problem is with either ribbon cable or CCM.
• On the inverter end put the ribbon cables back in their original positions. Now swap suspect ribbon
cable with another one on the CCM. If the fault now moves to a different section it's the ribbon cable. If
it remains with the original section the problem is the CCM.
231-236 Inverter VAC Mismatch.
Different inverter modules are manufactured for 480VAC, 380-415VAC & 208-230VAC operation voltages. There
is a key, called inverter ID, read through the inverter's ribbon cable, to identify which voltage range the inverter
is designed for. The unit itself is wired differently for the different input voltages and part of that includes a
jumper at J61 on the System Bias board that indicates to the System Bias board what voltage the unit is wired
to accept.
At power on, the System Bias board measures the incoming voltage, determines what input voltage range it
fall into and sends that range information to the CCM. Before Appling power to the inverters by turning on
the input contactors, the CCM checks that each connected inverter is of the correct voltage matching that of the
System Bias board. The inverter ID's are read from the lowest section to the highest so in all cases if it truly is a
wrong voltage inverter it should call out the A section whose code is read first. A VAC mismatch of a B section
is likely another problem.
Possible causes:
• Wrong voltage inverter (very unlikely but easy to check).
• System Bias board wrong J61 jumper (unlikely but easy to check)
• Defective inverter.
• Ribbon Cable
• CCM
• System Bias board defective.
Troubleshooting:
1. If System Bias board has either the wrong jumper or is defective it will call out the first inverter section, code
231, because all the inverters won't match the incorrect signal and 1A is checked first.
a. For the jumper Wire #48 should be connected from J61-1 to:
A-70
APPENDIX
Manual 0560956456