iSERIES 100 /200 /300 /400
615-617 No Update File for CCM, DPC or GSC found
Program files for the CCM, GSC & DPC may be updated through the plasma supply's USB port. Program
update files are in the format Cx_x_0.S (CCM); Mx_x_0.S (GSC) and Px_x_0.S (DPC).
If the Bootloader finds there are 3 devices, CCM, GSC & DPC on the CANBUS but the flash drive doesn't have
all 3 update files it will go ahead and update those it has but will show a code indicating that one or more are
missing (615 for CCM; 616 for GSC; 617 for DPC).
Try another flash drive or if you know this one is OK (it works with a computer), then replace the CCM.