Disconnect the motor power lead from the
wiring harness (repeat for motor at other end
of room).
3) Use 3/4"socket on gearbox
shaft. Crank both sides
equally to avoid wedging
2) Disconnect
motor power lead
from wiring harness
Slideout Motor/Gear Assembly
(Located beneath each end of
slideout room rail)
* Shown with slideout room extended
-Typical View
Use a 3/4" socket and ratchet wrench on the
motor gearbox shaft to crank the room in or
out as needed. Crank both sides of the room
alternately and equally to avoid wedging the
room.
If help is available, a second person (with a
duplicate socket and ratchet) cranking the
other end simultaneously will greatly speed
up the process.
Crank the room until it is just "snugged up."
Do not over-crank or you could damage the
gear assembly.
While maintaining pressure on ratchet
wrenches, re-engage the motor brake by
moving lever clockwise slightly (to right
when facing end of motor).
Reconnect motor power lead to wiring
harness.
Fasten slideout room travel latching device (if
equipped) inside the coach before driving the
vehicle.
See your dealer for service of the slideout
mechanism before using again.
1) Lift tab inside
protrusion on boot to
disengage motor brake
SLIDEOUT ROOMS AND LEVELING
Further Information
See the Under Floor Slideout Room operating
guide included in your InfoCase for further
instructions and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION – BEDROOM
(POWER GEAR
–If Equipped
If the slideout mechanism is malfunctioning
and the room will not retract using the control
switch, you may need to access the motor/gear
assembly and manually crank the room in to the
travel position.
The rear bedroom slideout has a motor/
gearbox unit, which is located underneath the
bed. Lift the bed board to access.
NOTE: If the bed in your coach is equipped with
the Power Lift feature, the bed must be
lowered completely before lifting the bed
board.
Crank-In Procedure
Disengage the motor brake, which appears as
a flat "square" protrusion on the protective
boot at the end of the motor. Move the brake
lever slightly – about 1/8 turn counter-
clockwise (to left when facing end of motor).
Disconnect the motor power lead from the
wiring harness.
Use a 3/4" socket and ratchet wrench on the
motor/gearbox shaft to crank the room in.