System Operation - Ideal Security SK662 Manual

Wireless water alarm system with auto-dialer
Table of Contents

Advertisement

Available languages

Available languages

BATTERY LOW INDICATOR
When the battery is low, the LED on the front of the unit will flash on 3 seconds and off 1 second. Replace the battery
immediately to maintain proper detection. If batteries are low they may send a false signal to the auto-dialer. Batteries in all
units should be replaced at least once per year.

SYSTEM OPERATION

1. TO ARM THE SYSTEM
• Enter password followed by the ARM/DISARM button.
• Three short beeps will sound and the ARM icon will show on the auto-dialer screen.
• Wait 60 seconds for a short beep. The auto-dialer is now set ARMED and ready to receive signals.
2. ALARM OPTIONS
• If the auto-dialer (in ARM mode) receives a signal from any sensor, the screen will display TRIGGER with the zone
number. After the entry time delay it will sound a SIREN for 30 seconds on, 30 seconds off and 30 seconds on, and will
automatically dial all the numbers stored, one by one, for the number of cycles (amount of times the numbers are dialed)
you have chosen. The receiver of the phone call will hear a prerecorded message and will have option to listen in or broad
cast to the room the auto-dialer is located in. The receiver of the call can then take appropriate action.
• In ARM mode, if the auto-dialer is set to SIREN OFF, the numbers stored will be dialed silently. No siren will be heard from
the auto-dialer.
3. TO DISARM THE SYSTEM FROM THE AUTO-DIALER KEY PAD
• Enter password followed by the ARM/DISARM button on the auto-dialer.
• You will hear one beep and the ARM icon will disappear from the auto-dialer screen to confirm that the auto-dialer has
been disarmed.
• The auto-dialer will detect if a phone line is connected before dialing, if no telephone line is connected the auto-dialer will
beep 4 times and the alarm will sound without dialing.
4. REMOTE OPERATION BY TELEPHONE
Description of remote operation features
• ROOM MONITOR – Enter "1 and #" after the beep you will be able to listen into the room where the auto-dialer is
installed. After 30 seconds you will hear a beep to remind you that if you do not enter another code within 20 seconds the
call will end. The total duration of the room monitor is 50 seconds if no other codes are entered.
• BROADCAST TO ROOM – Enter "2 and #" after the beep you will be able to broadcast into the room where the auto-
dialer is installed. After 30 seconds you will hear a beep to remind you that if you do not enter another code within 20
seconds the call will end. The total broadcast time is 50 seconds if no other codes are entered.
• END CALL – Enter "3 and #" after a beep the auto-dialer will hang up.
• ARM SYSTEM – Enter "5 and #" after three short beeps the system is ARMED and will automatically hang up. If you hear
5 rapid beeps after three short beeps, it means one of your sensors isn't closed or is activated. The system will give you 5
seconds to enter a new code.
• DISARM SYSTEM – Enter "6 and #" after a beep the auto-dialer will DISARM and hang up.
When you receive a call from the system :
• Answer the call. You will hear your personalized message.
• The message will repeat 3 times. If no function codes are entered by the receiver of the call, the system will hang up and
dial the next number programed.
• You may enter a key combination for the function you would like to perform, you will hear a beep for confirmation.
Call in features to control your auto-dialer via telephone
• Using a separate telephone line dial your home telephone number.
• The auto-dialer will answer after the set amount of rings that you programmed.
• Once connected enter your PASSWORD, you will hear two beeps (confirmation).
• Enter a key combination for the function you would like to perform, you will hear a beep for confirmation.
NOTE: Whether you receive an alarm call or you call the auto-dialer, if you enter a wrong password or operation code, the
call will disconnect and sound 5 beeps on the auto-dialer. If you have set the dialing sequence to more than one cycle, you