6. Initial start-up

Filling the cleaning fluid reservoir
Place the funnel supplied into the filling hole (Pic. 2, No. 11, page 7) and fill the fluid reservoir with the
Pure Groove
cleaning fluid provided (max. 0.4 l).
Pay attention to the LED level indicator so as not to over-fill. For effective cleaning we recommend using
only Clearaudio
Pure Groove
Opening the cleaning and vacuum arm and placing the record
Lift the upper cleaning arm and swing it to the left to open the cleaning and vacuum assembly.
Turn the knob of the Seal record clamp anticlockwise to release the clamp then place the record to be
cleaned on the label-sized platter. Now put the
gently while rotating the knob clockwise to secure the record in position and create a seal to protect the
record label from fluid damage.
Closing the cleaning and vacuum unit
Now you can swing the upper cleaning arm to the right to close the cleaning and vacuum assembly.
Automatic cleaning
The new features of the
fully automatic and efficient cleaning (see function 5.1, page 8). You only have to manually activate the
antistatic brush.
Manual cleaning
To set your own parameters for the cleaning process manually:
-
After you have placed and fixed the record with the
vacuum assembly.
-
Press the "Power" button to start the sonic cleaning function and rotation of the record.
-
Press the "Liquid" button to apply cleaning fluid to the record. Holding down the button for longer
applies more fluid. Adjust this according to the desired quantity of cleaning fluid.
-
After about 3 or 4 rotations, change the platter direction by pressing the "Platter" button.
We recommend 3 or 4 turns in each direction. By turning the "Platter Speed" knob you can vary the
rotational speed to further fine tune the cleaning process.
-
Once you are happy with the cleaning, press the "Vacuum" button. This will stop the sonic cleaning
function and start the vacuum drying process. After about 3 or 4 rotations, when the record is
visibly dry, switch off the suction by pressing the "Vacuum" button again.
-
Press the "Power" button to stop the record rotation.
-
Open the suction arm. Now start the antistatic function (see 5.3, page 21). After completion of the
antistatic function the manual cleaning is complete and you can remove your record.
© clearaudio electronic GmbH 2017
Double Matrix Professional Sonic
cleaning fluid (available at www.analogshop.de).
Seal
Double Matrix Professional Sonic
record clamp back on the spindle and press down
"Auto", "Superclean" and "ECO mode" provide
Seal
record clamp, close the cleaning and
User manaul
Bedienungsanleitung
Page / Seite 9