Waste fluid tank:
The waste fluid tank has a capacity of approx. 0.5 litres. We recommend regular draining of the tank, to
avoid any damage. Please note that with intensive use waste fluid can evaporate completely leaving
residue within the waste tank.
To empty the waste fluid tank:
1.
On the back panel you will find the drain tube, which can be pulled out (see Pic. 2, No. 10, page 7).
2.
Remove the sealing plug from the drain tube.
3.
To empty the waste fluid tank completely, tilt the
rear. Once emptied, be sure to reseal the drain tube again.
CAUTION:
Do not re-use waste cleaning fluid. This could damage your machine.
Cleaning the fluid reservoir:
The cleaning fluid reservoir has a capacity of approx. 0.4 litres. We recommend that you fill the tank only
Pure Groove
with Clearaudio
results.
CAUTION:
Never use foaming or corrosive liquids, or water. This could cause serious damage to your machine and
may void your warranty.
LED level indicator:
When the last LED (0%) of the level indicator is flashing (Pic. 2 No. 12, page 7), the functions "Auto",
"Superclean" and in manual mode, the function "Liquid", will be deactivated. This protects the liquid pump
from damage. To re-activate these functions, fill the cleaning fluid reservoir with more
fluid.
CAUTION:
Ensure that the Double Matrix Professional Sonic is switched on when filling the cleaning fluid reservoir so
that you can read the current level on the LED level indicator.
© clearaudio electronic GmbH 2017
Double Matrix Professional Sonic
cleaning fluid (available at www.analogshop.de) to receive the best cleaning
Pic. 5: Warning
Double Matrix Professional Sonic
User manaul
Bedienungsanleitung
about 45° to the
Pure Groove
cleaning
Page / Seite 11

Advertisement

Table of Contents
loading

Table of Contents