Specification - Deckma Hamburg OMD-2008 Instruction Manual

15ppm bilge alarm
Hide thumbs Also See for OMD-2008:
Table of Contents

Advertisement

4
Specification OMD-2008 EV FC
Range:
Accuracy
Linearity
Display
Power Supply:
Consumption:
Alarm Points 1 + 2:
Alarm 1 Operating Delay:
(for annunciation purpose)
Alarm 2 Operating Delay:
(for control purposes)
System Fault Alarm:
Alarm Contact Rating:
Alarm Indication:
Output Signal:
Sample Water Pressure:
Sample Flow:
Ambient Temperature:
Sample Water Temperature:
Roll:
Size (Computer Unit)
Size (EV-FC-Arrangement)
Degree of Protection:
Weight:
Pipe Connections:
Technical specifications are subject to change without notification
Issue: 08.07.2015
DECKMA HAMBURG GmbH
0 – 30 ppm, Trend indication 50ppm
According IMO MEPC. 107(49)
Up to 30 ppm better than ± 2 %
Yellow Graphic Display
24 V - 240V AC or DC
Automatic Voltage selection
< 10 VA
Adjustable between 1 - 15 ppm
(Works adjustment 15 ppm)
Adjustable between 1 – 540 sec.
(Works adjustment 2 sec)
Adjustable between 1 – 10 sec.
(Works adjustment 10 sec)
Red LED
Potential free 1 pole change over contacts,
3 A / 240 V
Red LEDs
0 – 20 mA or 4 – 20 selectable
ext. Load < 150 
0,1 – 10 bar
Approx. 0,1 - 3 l/min depending on pressure
+ 1 to + 55° C
+ 1 to + 65° C
Up to 45°
200 mm W x 200 mm H x 100 mm D
150 mm W x 290 mm H x 140 mm D
IP 65
5,9 kg
for 6mm OD Cu or SS pipe
Instruction Manual OMD-2008 (EV, FC, MCU Versions)
Page 6 of 28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents