Inspecting Results

Results are displayed according to the following categories as listed in
Table 4-2.
Table 4-2
Transmitter Rx Band Spurious Measurement Result Categories
Result
Units
category
Worst spur
Hz
frequency
Worst spur
dB
amplitude
Marker
Hz
frequency
Marker
dB
amplitude

Troubleshooting Hints

• If an external attenuator is used, be sure to include the attenuation
• If an external preamplifier is used, be sure to include the gain value
Chapter 4
Making The Transmitter Receive (Rx) Band Spurious Measurement
Min
Max
N/A
N/A
–200
100
N/A
N/A
–200
100
value in the measurement. This can be done under the
menu or by using a negative value for
Ext Atten
.
Gain
in the measurement.
Making GSM Air Interface Measurements
Description
Displays the frequency of the highest peak
from all segments, or from the current
segment if in examine mode.
Displays the amplitude of the highest peak
from all segments, or from the current
segment if in Examine mode.
Displays the frequency of the active marker.
Disabled if no markers are active.
Displays the amplitude of the active marker.
Disabled if no markers are active.