7-2-11

Windows Blue Screens

A blue screen will appear if Windows crashes.
Possible solutions for repetitive blue screens:
1
Install the latest updates of Windows.
2
Install the latest device drivers.
3
If changes to the system were made: Undo recent hardware changes, undo recent driver up-
dates and then roll back system to latest working state.
Additional Information
Refer to http://windows.microsoft.com/en-us/windows7/resolving-stop-blue-screen-errors-in-
windows-7 for details.
7-2-12

Correct Display Functionality when Nothing is Displayed

When it seems the display is not functional, check the ERR LED.
• If the ERR LED is OFF
• Check if the power supply is present.
Refer to 4-1-2 General Electrical Specifications on page 4 - 3 for power supply specifications.
• Check if the brightness setting is not too low.
Refer to Industrial Monitor Utility for brightness details.
The Industrial Monitor Utility information is available:
• For products NYP£ in the section Software in this manual.
• For products NY5£ in the NY-series IPC Machine Controller Industrial Panel PC / Industrial
Box PC Setup User's Manual (Cat. No. W568)
• If the ERR LED is blinking check if the Panel PC is not in standby mode.
• If the ERR LED is ON
• Check if the power supply voltage is inside specifications.
Refer to 4-1-2 General Electrical Specifications on page 4 - 3 for power supply specifications.
• Check if the ambient temperature is inside specifications.
Refer to 4-5-1 Operation Environment Specifications on page 4 - 25 for temperature specifica-
tions.
• Check if the Fan Unit has no warning messages.
Refer to ERR LED Indicator on page 2 - 6 for message details.
• Check if a watchdog error occurred.
The watchdog is disabled by default and can only be enabled by software using the Industrial PC
System API.
The API information is available:
• For products NYP£ in the section Software.
• For products NY5£ refer to the NY-series IPC Machine Controller Industrial Panel PC / Industri-
al Box PC Setup User's Manual (Cat. No. W568)
NY-series Industrial Panel PC User's Manual (W555)