6.2 Check-In Supervision

S
:
PECTRA
SECTION
D
IGIPLEX SERIES
With check-in supervision enabled, the MG-RCV3 waits for each of its
assigned transmitters to send a status signal within a specified time period to
confirm their presence and functionality. If a transmitter has not sent a signal
within that time period, the module will transmit a supervision loss signal to the
control panel. The control panel can then generate a trouble, an alarm and/or
can transmit a report code to the monitoring station (refer to the Spectra or
appropriate Digiplex series Reference & Installation Manual).
How to enable/disable check-in supervision:
Spectra
In step 3 in section 3.1 on page 8:
1. Enter section [610].
2. Enable or disable option [1].
Digiplex Series
In step 5 in section 3.2 on page 8:
1. Enter section [001].
2. Enable or disable option [2].

6.2.1 Check-in Supervision Time Interval

S
PECTRA
D
IGIPLEX SERIES
With check-in supervision enabled, the check-in supervision time
interval defines the time period the MG-RCV3 will expect a check-in
status from its assigned wireless transmitters. If the module does not
receive a signal from one of its wireless transmitters within the time
period defined here, a trouble and an alarm will be generated and/or a
report code will be transmitted to the central station.
16
[610]:
OPTION
:
[001]:
SECTION
Option [1] OFF = Check-in Supervision disabled (default)
Option [1] ON = Check-in Supervision enabled
Option [2] OFF= Check-in Supervision disabled (default)
Option [2] ON = Check-in Supervision enabled
:
[610]:
SECTION
:
SECTION
[1]
[2]
OPTION
[2]
OPTION
[001]:
[3]
OPTION
Reference & Installation Manual

Advertisement

Table of Contents
loading

Table of Contents