52
ENGINE OPERATION
1. Neutral (N)
2. Control lever
3. Fully opened (Forward)
4. Fully opened (Reverse)
5. Free throttle lever
6. Main switch key
7. Stop switch
4. Turn the main switch key to ON posi-
tion and confirm three warning lamps
light up with buzzer sound and then go
off.
7
1. Warning lamp
5. Turn the main switch key to START
position and release the key when the
engine has started. The key returns to
the original position, automatically.
1. ON
2. START
3. OFF
ENON00035-A
Note
The free throttle lever can not be raised
when the control lever shift is in Forward or
Reverse.
1
ENOF00851-0
1
2
3
ENOF00871-0
6. Check the cooling water from cooling
water check port.
1
1. Idle port
2. Cooling water check port 40, 50
1
1. Idle port
2. Cooling water check port 75, 90, 115
ENOM00042-A

Emergency starting

*Only for 40, 50
ENOW00099-A
WARNING
When the emergency starter rope is used
for starting engine;
Start in gear protection does not work.
Be sure to shift is at neutral position.
Otherwise the engine will move the boat
immediately and cause personal injury.
Be careful that your clothes or other
items do not get caught in the rotating
engine parts.
To prevent accident and injury by rotat-
ing parts, do not re-attach flywheel
cover and the top cowl after the engine
has been started.
2
ENOF00664-0
2
ENOF00665-0