Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Datron Manuals
Multimeter
4708
User handbook manual
Datron 4708 User Handbook Manual page 85
Autocal multifunction standard
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
page
of
150
Go
/
150
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
DC
Current
Verification
Procedure
Record
results
on Report
Sheet
4708
RS
1,
(Page
7-33).
Full
Range Checks
(100|iA
-
1A)
N.B.
Values
in
square brackets
[ ... ]
apply
when
the
DMM
is
to
be
standardized
for the
1
A
Range
at
100mA,
using
the preferred transfer
shunt value of
0.
Ifi.
Standardize
the
DMM
at
IV
[lOOmV]:
Ensure
that
the
4708
has already
been
verified
on
its
IV
and
lOOmV
ranges.
Ensure
that the
DMM
has
been
recently
calibrated,
or
that
its
zero-offsets
have been removed, and
its
polarity
turnover
at
IV
[lOOmV]
is
verified as accurate.
Standardize
the
DMM
before verifying
the
ranges
in
the
sequence of
RS
1
Table
2;
a.
4708
Set
OUTPUT
OFF,
FUNCTION
to
DC,
OUTPUT RANGE
to
1
[100m],
Sense and
Guard
to
Remote.
OUTPUT
Display
to
+ 1.0000000
V
[+100.00000mV]
b
.
Connect
the
DMM
to
read
the
4708
output
for
standardization
(no
shunt).
Observe
the correct
DMM
Guard
selections.
c.
DMM
Set
to
measure
IV
[lOOmV] DC.
d.
4708
Set
OUTPUT
ON.
e.
DMM
Note
the
reading
as
'+vr.
f.
4708
Set
OUTPUT
OFF.
g
.
Disconnect
the
4708
from
the
DMM.
7-9
Table of
Contents
Previous
Page
Next
Page
1
...
82
83
84
85
86
87
88
89
Show Quick Links
Quick Links:
The Datron 4708 Autocal Multifunction Standard
DC Voltage Outputs
DC Current
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Datron 4708
Multimeter Datron 1062 Service Handbook
(202 pages)
Related Products for Datron 4708
Datron 4910
Datron 4911
Datron 1061
Datron 1061a
Datron 1062
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL