Autocal multifunction standard
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
page
of
150
Go
/
150
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Two
sorts
of
terminator are
available:
a.
One
or
two
bytes
can
be added
to the
end
of
the
string.
These
contain
either
Carriage Return
(Cr)
or
Line
Feed
(LO;
or
both
in
the order:
Cr
followed
by
Lf.
b.
The
EOI
bus
management
line
can be
programmed
to set
true
simultaneously with
the
last
byte
of
the
string.
EOI
can
be used even
if
both
Cr
and Lf
are suppressed.
The 4708
can
also
be
programmed
to
transmit
strings
without
terminators.
To
accommodate
these
variations,
the
system
programmer
uses
the
K
codes:
K0
-
No
suppression (Cr,
Lf
and
EOI
all
pres-
ent as terminators)
K1
Suppress
EOI
(Terminator
Cr
followed
byLf)
K2
Suppress
Lf
(Terminator
Cr
with
EOI)
K3
-
Suppress
Lf and
EOI
(Terminator
Cr)
K4
Suppress
Cr
(Terminator
Lf
with
EOI)
K5
-
Suppress
Cr
and
EOI
(Terminator Lf)
K6
-
Suppress
Cr
and
Lf
(Terminator
EOI
with
last
character)
K7
-
Suppress
Cr,
Lf
and
EOI
(No
terminators)
Descriptive
Legends
The
following
Legends
will
be
fitted
into the string
after
the exponent,
if
programmed by
codes
L0
or L2:
5-12
Table of
Contents
Previous
Page
Next
Page
1
...
57
58
59
60
61
62
63
64
Show Quick Links
Quick Links:
The Datron 4708 Autocal Multifunction Standard
DC Voltage Outputs
DC Current
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Datron 4708
Multimeter Datron 1062 Service Handbook
(202 pages)
Related Products for Datron 4708
Datron 4910
Datron 4911
Datron 1061
Datron 1061a
Datron 1062
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL