Datron 4708 User Handbook Manual page 57

Autocal multifunction standard
Table of Contents

Advertisement

Output
Resolution
The
output
resolution
conforms
to
the
following
number
of
Range
100|a
Im
lOm
100m
1
10
100
1000
DCV,
ACV
DCI,
ACI
10
100
Ik
10k
100k
Im
10m
100m
a
Range Code
Rl
R2
R3
R4
R5
R6
R7
R8
Functions:
DC
Voltage
F0
4.5
5.5
6.5
7.5
7.5
7.5
7.5
7.5
AC
Voltage
FI
-
4.5
5.5
6.5
6.5
6.5
6.5
6.5
DC
Current
F2
6.5
6.5
6.5
6.5
6.5
-
-
-
AC
Current
F3
6.5
6.5
6.5
6.5
6.5
-
-
-
Resistance
F4)
and Local
)
4.5
5.5
6.5
7.5
7.5
7.5
7.5
7.5
Sense
S0)
Resistance
F4)
and
Remote
)
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Sense
SI)
Frequency
Display
Value
(Auxiliary Register)
In
remote programming,
the
incremental
(t
^
)
method
of
setting
the
frequency
is
not
used.
Instead,
each
auxiliary
register
value
is
input
explicitly
by
Code H****
in
numeric,
scientific
or engineering
notation.
The
manual
frequency
'Store'
memories
cannot be
set
via the
bus,
although
their
contents
can be read using
'V' codes.
Frequency
Resolution
Frequency
is
resolved
to
three significant
digits
(1%
to
lOOppm
accuracy).
On
the display
this
occupies four
digit
spaces,
to
accommodate
the
decimal
point.
If
the significance
is
greater
than
three
digits,
the
value
is
truncated
and
the controller
is
informed by
SRQ
Status
byte
(see
SRQ
status
byte formats
later
in
this
section).
Frequency and
Voltage Constraints
On
lOOV
and
lOOOV
output ranges,
the
4708
will
refuse
any
command
for
an output
which
exceeds
the limits
defined
on
page
3-7.
The
controller
is
informed by 'Error
7'
SRQ
status
byte
(see
SRQ
status
byte formats
later in this
section).
Spot Frequency
Selection
Codes
T1-T5
select the
spot frequencies stored
in
SF1-SF5
non-
volatile
memories.
Sixty
unique
memory
locations
exist.
Thirty
five are
allocated
to
the
seven
AC
Voltage
output ranges
and
twenty
five to the five
AC
Current
ranges:
five for
each
range.
The
value of
the
frequeney
called
up by any
T
command
is
therefore
dependent on
the
preselected
F
and
R
codes.
With
spot
active,
sending a
new
R
code
selects
the
correspond-
ing spot
frequency
in
the
new
range.
A
new F
code,
sent
to
change
function,
cancels the
T
command:
the
4708
frequency
reverts
to
IkHz.
The
controller
is
able
to
command
an
uncalibrated
spot.
The
'uncalibrated'
message
is
displayed
as
in
manual
operation,
the
4708
frequency remaining
as
previously
set.
But
in
addition,
the
4708
generates
an
SRQ
to
notify the
controller.
Code
T0
cancels
any
earlier
spot
frequency
selection:
the4708
frequency
reverts
to
IkHz.
N.B.
The
Spot Frequency
facility
is
included
to
provide
separate, ultra-accurately calibrated
points
in
the
4708
output
spectrum. Therefore, frequencies
set into the 'spot
frequency'
memories
can only be
changed
during
the
Autocal
routine (See
Section
8).
Guard and Sense
These
are
configured
into
Local
or
Remote
by
G
or
S
codes
respectively:
G0
-
Local
Guard
G1
-
Remote Guard
50
-
Local Sense
(forced
when F2
or
F3
has
been
commanded
and
when
FO,
Rl,
R2,
R3
and
R4
or
FI
,
R2,
R3
and
R4
have been
commanded). Programs
for
2-wire
resis-
tance
in
F4.
51
-
Remote
Sense
(available
only
when FO
or
FI have been
selected together
with R5,
R6,
R7
and
R8
or
when
F4
has
been
selected
in
all
ranges).
Programs
for 4-
wire
resistance
in
F4.
5-9