Rear Panel - Datron 4708 User Handbook Manual

Autocal multifunction standard
Table of Contents

Advertisement

With Remote
Sense
ON,
the
output voltage
is
fed across the
1+
and
I-
terminals only,
and must be
sensed
externally,
using
leads
connected
to
the
Hi
and
Lo
terminals.
Remote
Sense
is
not available
on
lOOjiV
-
lOOmV
ranges.
It
is
not applicable
to
Current
outputs.
On
Ohms
ranges.
Local Sense
is
used
for
2-wire connections,
and
Remote
Sense
for 4-wire.
(Changing
FUNCTION
into Q,
forces the
4708
into
Remote
Sense, but
this
may
be
deselected
for
2-wire
operation).
The
Remote
Sense
LED
always
indi-
cates the true
connection:
Lit
=
Remote;
Unlit
=
Local
Guard
Terminal
The Guard
terminal
is
permanently connected
to
the
internal
guard
shields:
Remote
Guard
The Remote Guard
key
has
'toggle' action.
Successive
presses
alternate
between
ON
and
OFF.
With Remote Guard OFF,
Guard
is
internally
connected
to
the
I-
terminal.
With Remote Guard
ON,
the internal link to
I-
is
removed.
The Guard
terminal
can
then
be connected
externally
to
reduce
common
mode
interference.
Ground
Terminal
The
Ground
terminal
connects
directly to the
4708
internal
Ground
shields
and
to
Safety
Ground
via the
power
cable.
Output Connections
Connections
to
the
output
terminals
may
be
made
either
with
leads or via a
shrouded
connector.
For
Voltage
outputs
in
local
sense
the
two
leads
should be
attached
to the
Hi and
Lo
terminals.
Various
configurations
of
4708
load connections are
detailed
in
Section
4.
REAR
PANEL
(Shown
with
alternative
Rear Ouqjut
terminals)
i
n
DATRON
INSTRUMENTS
(
I
I
«
1
POWER
INPUT
The
recessed
POWER
INPUT
plug,
POWER
FUSE
and
LINE
VOLTAGE
SELECTOR
are located
in
the center
of
the
rear panel,
contained within a
single
moulded
unit.
Details
of
connections,
selection
of
line
voltage
and
fuse are given
in
Section
2,
REAR OUTPUT
ALTERNATIVE
(Option
42)
This can be
incorporated
at
manufacture,
to
provide
six
output
terminals
on
the rear
panel
instead
of
the six
on
the
front.
Their
functions
and
connections
are
identical.
SOCKET
J53
(External
Reference Frequency
Input)
This
BNC
socket
is
located next
to
the
cooling
air
intake
filter.
It
may
be used
to
lock
the internal
frequency
synthesizer
to
a
customer's
own
frequency
standard.
Voltage and
frequency
criteria
are
given
in
Section
2.
An
on-off
switch,
S53,
located
above
this
socket
is
provided
to
enable
this facility. If
the switch
is
on and
an
external
frequency
is
not
present, error
message
'Error
EF'
is
displayed.
3-11

Hide quick links:

Advertisement

Table of Contents
loading