Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Datron Manuals
Multimeter
4708
User handbook manual
Datron 4708 User Handbook Manual page 106
Autocal multifunction standard
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
page
of
150
Go
/
150
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
1.
DC VOLTAGE
a.
Full
Range Checks
Validity
Tolerance:
Lower
Limit
=
Lr-
Ud(Abs)
-
Us(Abs);
Upper
Limit
= Ur
Ud(Abs)
Us(Abs)
4708
4708
Relative
Accuracy
Datron
User's
Validity
Tolerance
Limits
User's
OUTPUT
OUTPUT
Tolerance
Limits
Cal. Std.
Cal. Std.
DC
Standard
POLARITY/
Display
Uncerfy.
Uncerfy.
value
for
RANGE
Setting
Lower(Lr)
Upper(Ur)
±Ud(Abs)
±Us(Abs)
Lower
Upper
Null
+
lOO^V
+100.00^V
+99.60
+100.40
O.OOpV
-
lOOpV
-lOO.OOpV
-100.40
-99.60
O.OOpV
+
ImV
+1.00000mV
+0.99960
+1.00040
.OOOOOmV
-
ImV
-I.OOOOOmV
-1.00040
-0.99960
.OOOOOmV
+
lOmV
+10.00000mV
+9.99957
+10.00043
0.00004mV
-
lOmV
-lO.OOOOOmV
-10.00043
-9.99957
0.00004mV
+
lOOmV
+100.00000mV
+99.99930
+100.00070
0.00040mV
-
lOOmV
-lOO.OOOOOmV
-100.00070
-99.99930
0.00040mV
+
IV
+1.0000000V
+.9999972
1.0000028
.0000020V
-
IV
-1.0000000V
-1.0000028
-.9999972
0000020V
+
10V
+10.000000V
+9.999987
+10.000013
0.000015V
BSH
b.
Linearity
Validity
Tolerance:
Lower
Limit
=
Lr
-
Ud(Abs)
-
Us(Abs);
Upper
Limit
= Ur + Ud(Abs) + Us(Abs)
(Performed on
10V Range)
4708
Relative
Accuracy
Datron
User's
Validity
Tolerance
Limits
User's
POLARITY/
Tolerance
Limits
Cal. Std.
Cal. Std.
DC
Standard
NOMINAL
Uncerfy.
Uncerfy.
value
for
VALUE
Lower
(Lr)
Upper
(Ur)
±Ud(Abs)
±Us(Abs)
Lower
Upper
Null
+
OV
-0.000003V
+0.000003V
.OOOOOOV
-
OV
-0.000003V
+0.000003V
.OOOOOOV
+
IV
+0.999996V
+
1.000004V
.000002V
-
IV
-1.000004V
-0.999996V
.000002V
+
10V
+9.999987V
+10.000013V
,000015V
-
10V
-10.000013V
+9.999987V
,000015V
+
19V
+1
8.999978V
+1
9.000022V
.000029V
-
19V
-19.000022V
-18.999978V
000029V
c.
High Voltage
Full
Range Checks
Validity
Tolerance:
Lower
Limit
=
Lr
-
Ud(Abs)
-
Us(Abs);
Upper
Limit
= Ur + Ud(Abs) + Us(Abs)
4708
4708
Relative
Accuracy
Datron
User's
Validity
Tolerance
Limits
User's
OUTPUT
OUTPUT
Tolerance
Limits
Cal. Std.
Cal. Std.
DC
Standard
POLARITY/
Display
Uncerfy.
Uncerfy.
value
for
RANGE
Setting
Lower(Lr)
Upper(Ur)
±Ud(Abs)
±Us(Abs)
Lower
Upper
Null
+
100
V
+100.00000V
+99.99975
+100.00025
0.00020V
-
100V
-100.00000V
-100.00025
-99.99975
0.00020V
+
1000V
+
1000.0000V
+999.9965
+1000.0035
0.0020V
-
1000V
-1000.0000V
7-31
4708
RS
U2
Table of
Contents
Previous
Page
Next
Page
1
...
105
106
107
108
Show Quick Links
Quick Links:
The Datron 4708 Autocal Multifunction Standard
DC Voltage Outputs
DC Current
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Datron 4708
Multimeter Datron 1062 Service Handbook
(202 pages)
Related Products for Datron 4708
Datron 4910
Datron 4911
Datron 1061
Datron 1061a
Datron 1062
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL