Normal operation
Alarm / emergency
Fig. 32: Connection for emergency stop / fire alarm switch
Automatic starting and stopping
WhisperPower cannot be held responsible for
damage caused by the unattended running
generator using the auto-start/stop mode or
interval mode.
Using the auto-start/stop (interval) mode the
generator can start unexpectedly. When
working on the electrical system, the 3 Amp
fuse must be removed from the control panel
and the battery plus cable must be removed
from the battery.
In the delivery are warning stickers to stick on
several parts of the electric installation
(transfer switch, distribution box, etc.) to warn
for automatic start).
The WhisperPower Digital Diesel Control system offers
several options for automatic starting and stopping.
Access to this menu and other menus could be blocked.
For de-blocking and setting up this options refer to the
APPENDIX of the DDC user's manual.
One of these options is to monitor a second battery (not
being
the
starter
battery)
automatically when the voltage of this battery drops below
a certain setting.
Other names for this second battery are "auxiliary battery",
"service battery", "users battery" or "consumers battery".
We will refer to this battery as "the second battery"(BAT2).
In some menus the starter battery could be indicated as
"the first battery" (BAT1).
A sense wire to monitor the second battery should be
connected (attention polarity!) to the connector on the
EN / W-SQ6/8/12/16 for mobile applications / December 2016
Remove bypass
between J7 - J18
local control panel
(rear view)
to
start
the
generator
back of the remote panel. Refer to fig. 31. The sense wires
must be connected directly on the second battery before a
main switch and be protected by a 3 Amps fuse.
(Monitoring the generator starter battery does not require
an extra sense connection).
Settings
When one want to apply other settings than the factory
settings refer to the DDC user's manual, especially to the
APPENDIX.
2
STARTER BATTERY
For starting, the engine requires a 12V starter battery with
the following capacity:
Model
W-SQ6, 8, 12
W-SQ16
The generating set can be connected with the main engine
battery or have its own battery.
We strongly recommend the use of a separate battery for
the generating set and to keep the wiring system for the
vehicle engine and the domestic DC supply system
completely
separate
and
separate batteries.
Fig. 33: Starter battery
However, the negative of all the batteries on the vehicle
should be interconnected to avoid difference in the voltage
level of the earth on different places causing trouble to
electronic devices which might be in the system.
The above recommendation is not valid for vehicles having
the starter battery of the vehicle engine or other auxiliary
equipment positive grounded. When this is the case an
expert should be consulted.
A battery switch may be used to interrupt the positive
connection.
The starter battery is charged by the alternator on the
engine. An additional battery charger will help to keep the
battery in good condition when the generating set is not
used.
A battery charger is not included in the standard supply. A
high efficiency battery charging unit can be ordered from
WhisperPower which is able to charge both the vehicles's
INSTALLATION
Capacity
80Ah
100Ah
individually
connected
to
21