Physical And Electrical Specifications - IBM System x3650 M4 HD Product Manual

Table of Contents

Advertisement

Physical and electrical specifications

Dimensions and weight:
Height: 86.5 mm (3.4 in.)
Width: 445 mm (17.5 in.)
Depth: 746 mm (29.4 in.)
Weight:
Minimum configuration: 25 kg (55 lb)
Maximum configuration: 30 kg (65 lb)
Supported environment:
The IBM System x3650 M4 HD complies with ASHRAE class A3 specifications.
Power on:
Temperature: 5 °C to 40 °C (41 °F to 104 °F) up to 950 m (3,117 ft)
Above 950 m, de-rated maximum air temperature 1 °C / 175 m
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8% - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3050 m (10,000 ft) and 5 °C to 28 °C (41 °F to 82 °F)
Maximum rate of temperature change: 20 °C/hr (68 °F/hr) for HDDs
Power off:
Temperature: 5 °C to 45 °C (41 °F to 113 °F)
Relative humidity: 8% - 85%
Maximum dew point: 27 °C (80.6 °F)
Storage (non-operating):
Temperature: 1 °C to 60 °C (33.8 °F to 140 °F)
Altitude: 3050 m (10,000 ft)
Relative humidity: 5% - 80%
Maximum dew point: 29 °C (84.2 °F)
Shipment (non-operating):
Temperature: -40 °C to 60 °C (-40 °F to 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5% - 100%
Maximum dew point: 29 °C (84.2 °F)
Electrical:
Models with 900 W power supplies:
100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A
200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.2 kVA
Models with 750 W AC power supplies:
100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 8.9 A
200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 0.99 kVA
IBM System x3650 M4 HD
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents