Physical And Electrical Specifications - IBM x3650 M3 Product Manual

Hide thumbs Also See for x3650 M3:
Table of Contents

Advertisement

VMware ESX 4.1
VMware ESXi 4.0
VMware ESXi 4.1
VMware vSphere 5.0 (ESXi)
VMware vSphere 5.1 (ESXi)
VMware vSphere 5.5 (ESXi)
See the IBM ServerProven® website for the latest information about the specific versions and service
levels supported and any other prerequisites:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

Dimensions and weight:
Height: 85 mm (3.36 in)
Width: 443 mm (17.5 in)
Depth: 698 mm (27.5 in)
Weight:
Minimum configuration: 21.1 kg (46.5 lb)
Maximum configuration: 29.6 kg (65 lb)
Supported environment:
Air temperature
Server on: 10 to 35° C (50 to 95° F); altitude: 0 to 914 m (3,000 ft). Decrease system temperature
by 0.75° C for every 1,000-foot increase in altitude.
Server off: 5 to 45° C (41 to 113° F)
Shipment: -40 to +60° C (-40 to 140° F)
Humidity
Server on: 20 to 80%; maximum dew point 21° C; maximum rate of change 5° C/hr
Server off: 8 to 80%; maximum dew point 27° C
Electrical
Models with 675 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 7.8 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.78 kVA
Models with 460 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 2.6 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.53 kVA
BTU output
Minimum configuration: 307 Btu/hr (90 watts)
Maximum configuration: 2260 Btu/hr (780 watts)