Other Considerations; Display Error Codes - Extech Instruments DT500 User Manual

Laser distance finder
Table of Contents

Advertisement

Other Considerations 
Range considerations 
The range is limited to 70m (230'). At night or dusk if the target is in shadow the measuring 
range without target plate is increased. Use a target plate to increase the measurement range 
during daylight or if the target has poor reflection properties. In unfavorable conditions such as 
intense sunlight, poor reflective surfaces, or high temperatures distances over 10m (33ft.) can 
increase by ±0.15mm/m (±0.0018in/ft.) 
Target surfaces 
Measurement errors can occur when measuring toward colorless liquids (e.g. water), dust free 
glass, Styrofoam or similar semi‐permeable surfaces. Aiming at high gloss surfaces may deflect 
the laser beam and lead to measurement errors. Against non‐reflective and dark surfaces the 
measuring time may increase. 
Care 
Do  not  immerse  the  instrument  in  water.  Wipe  off  dirt  with  a  damp,  soft  cloth.  Do  not  use 
aggressive cleaning agents, solvents, abrasives, or such solutions. Handle the instrument as you 
would a telescope or camera. 
 
 
Display Error Codes 
For any error codes, cycle power to the instrument to see if the error clears. If the error persists 
after several power cycles, following the directives below. Note that a 'wrench' icon appears 
with error code displays. 
204 – Calculation Error (retry the procedure) 
208 – Received signal too weak. Measurement time is too long. Distance >50m (Use target plate) 
209 – Received signal too strong (Target too reflective, use a target plate) 
252 – High Temperature (Cool down the instrument) 
253 – Low Temperature (Warm up the instrument) 
255 – Hardware error (Return the instrument for service) 
  
 