4
4.1
4.2
4.2.1
4.2.2
4.3
4.3.1
c
n
0312266_INNOVO_UKUK_V3.0, 2017-02-10
Use
Set a parameter value
To set a parameter value:
1.
Press [MENU] to access the user menu.
2.
Press [ ] or [ ] to scroll to the concerning parameter, refer to Parameters (see
section 3.1.3).
3.
Press [ENTER] to select.
4.
Use [ ] or [ ] to change the parameter value.
a.
Press [ENTER] to confirm.
b.
Press [RESET] to go back to the main menu.
5.
Press [RESET] to leave the user menu.
Turn on the water heater
To start the water heater:
1.
Make sure the water heater connects to the mains power supply.
2.
Set the control switch on the side of the water (see section 1) heater to I.
The display will show ini for about 10 seconds.
3.
When the display shows OFF the water heater is ready to use.
Switch to ON mode
To switch to ON mode (see section 3.2.1.2), change parameter 001 to ON, refer to Set a
parameter value (see section 4.1).
Set the water temperature
To change the temperature setpoint:
•
Adjust parameter 002, refer to Set a parameter value (see section 4.1), or
•
Directly from ON mode:
a.
Directly use [ ] or [ ] to set the temperature value.
b.
Press [ENTER] to confirm.
Turn off the water heater
Turn off for a short period
To turn off the water heater for less than 2 months, change parameter 001 to OFF, refer to
Set a parameter value (see section 4.1).
The water heater will switch to OFF mode (see section 3.2.1.1) and the frost protection is
on.
Caution
The anode protection remains active when the OFF mode is selected.
Note
If the water heater is in OFF mode for more than 2 months and no water is drained, air
bubbles may be formed in the water heater. This can lead to air in the water pipes.
25