Code and description
S02 (blocking error)
Sensor error
Open circuit from sensor 1
of the temperature sensor
S03 (blocking error)
Sensor error
Open circuit from sensor 2
of the temperature sensor
S12 (blocking error)
Sensor error
Short circuit in sensor 1 of
the temperature sensor
S13 (blocking error)
Sensor error
Short circuit in sensor 2 of
the temperature sensor
0312266_INNOVO_UKUK_V3.0, 2017-02-10
Cause
Sensor is not (correctly) connected.
Damaged wiring and/or defective
sensor.
Sensor is not (correctly) connected.
Damaged wiring and/or defective
sensor.
Short circuit in the sensor circuit.
Short circuit in the sensor circuit.
Measure
Make sure that the connector is
connected to J3.
Make sure that the wire is connected to
the sensor.
Replace the wiring and/or sensor.
Make sure that the connector is
connected to J3.
Make sure that the wire is connected to
the sensor.
Replace the wiring and/or sensor.
Replace the wiring and/or sensor.
Replace the wiring and/or sensor.