13
13.1
Description
General
Capacity
Empty Weight
Maximum floor load
Maximum operating pressure
- installation
Maximum operating pressure
- tank
Control thermostat -
adjustment range
Control thermostat - default
value
Hysteresis upwards -
adjustment range
Hysteresis upwards - default
value
Number of (electrical) anodes -
Minimum measured air
pressure differential across
the pressure switch
Setpoint pressure switch
Heating time ΔT = 45 °C
Electrical
Electrical power consumption
(peak)
Electrical power consumption
(nominal)
Supply voltage/Main
frequency
IP-class
0312266_INNOVO_UKUK_V3.0, 2017-02-10

Appendices

Technical details

Unit
IR-12-160
IR-20-160
l
160
kg
95
kg
255
kPa (bar)
550 (5.5)
kPa (bar)
800 (8)
°C
40...85
°C
65
°C
2...15
°C
10
1
Pa
≥ 210
Pa
175
min.
28
(12-160)
18
(20-160)
W
85
W
25
(12-160)
36
(20-160)
VAC / Hz
-
IR-12-200
IR-24-245
IR-20-200
IR-32-245
200
245
106
120
306
365
550 (5.5)
550 (5.5)
800 (8)
800 (8)
40...85
40...85
65
65
2...15
2...15
10
10
1
2
≥ 210
≥ 460
175
400
43
26
(12-200)
(24-245)
28
20
(20-200)
(32-245)
85
105
25
51
(12-200)
(24-245)
36
85
(20-200)
(32-245)
230 (-15%, +10%) / 50 (± 1)
IP20
IR-24-285
IR-32-380
IR-32-285
285
380
136
155
421
535
550 (5.5)
550 (5.5)
800 (8)
800 (8)
40...85
40...85
65
65
2...15
2...15
10
10
2
2
≥ 460
≥ 460
400
400
33
32
(24-285)
25
(32-285)
105
105
51
85
(24-285)
85
(32-285)
81