Clean The Combustion Chamber; Assemble The Burner - A.O. Smith Innovo 12-160 Installation, Service & Maintenance Manual

Condensing high-efficiency water heater
Table of Contents

Advertisement

11.4.2
11.4.3
n
0312266_INNOVO_UKUK_V3.0, 2017-02-10
Fig. Disassemble the burner assembly
13
12
10
9
8
9
11
Use compressed air to remove all contamination from the outside to the inside of the
burner (7).

Clean the combustion chamber

Use a vacuum cleaner and a soft brush to clean the combustion chamber (1) of the heat
exchanger.
Fig. Combustion chamber

Assemble the burner

Assemble the burner again when the burner and the combustion chamber both are
cleaned.
Note
Before reassembly replace the gasket, bolts and washers. You can order a special gasket
and mounting set at your supplier. Look at the data plate for the correct ordering
information.
15
14
1
8. Non return
valve
9. Bolts
10. Hot surface
igniter
11. Flame rod
12. Adapter
13. Gasket
14. Burner
15. Burner
flange
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents