Changing The Batteries (Ec 24) - RMG EC 24 Operating Instructions Manual

Volume corrector and temperature corrector
Hide thumbs Also See for EC 24:
Table of Contents

Advertisement

OPERATION
...........................................................................................................................................................................................................

Changing the batteries (EC 24)

The two batteries of the EC 24 can easily be changed without opening the corrector. On the left
side of the casing, there is a round slotted cover which can be screwed out. Behind this cover,
there is the battery holder. In hazardous areas disconnect the battery holder and change the
batteries in a safe area. Afterwards connect the battery holder again (see figure) and push it into
the battery compartment. Now screw in the cover again and the battery change is terminated.
28
In safe areas the batteries can be changed directly without disconnecting the battery holder.
If you use other batteries than the replacement batteries from RMG, you run the risk of
the EC 24 not being approved for areas subject to explosion hazards any more.
In areas subject to explosion hazards, you must never insert or remove the batteries.
Remove the battery holder from the case and change the batteries in an area without
explosion hazards.
...........................................................................................................................................................................................................
red
blue
blue
red
Manual EC 24 · EN05 · 2015-02