Totalizers; Flow Rate; Pressure - RMG EC 24 Operating Instructions Manual

Volume corrector and temperature corrector
Hide thumbs Also See for EC 24:
Table of Contents

Advertisement

OPERATION
...........................................................................................................................................................................................................

Totalizers

Pointer position
Coordinate /
Coding
S
S
S
22
S
S
S
D

Flow rate

Pointer position
Coding
D
D
D
S
S
D
S
S

Pressure

Pointer position
Coding
D
S
S
S
C
D
D
D
S
S
S
S
S
...........................................................................................................................................................................................................
A
Line
1
Nm3
2
m3
3
VbD
Disturbing quantity totalizer, volume at base conditions
Disturbing quantity totalizer, volume at measurement
4
VmD
5
I/m3
6
I/m3
9 ... 22
Coordinate /
B
Line
1
N3H
2
m3/h
3
F
4
Qm<
5
Qm>
6
Qmx
7
qug
8
qmt
Coordinate /
C
Line
1
bar
2
p<
3
p>
4
pb
5
p-def
6
Dig
7
Dig
8
Dig
9
Umi
10
pmi
11
p-S
12
pA0
13
pA1
Description of the coordinate
Main totalizer, volume at base conditions
Main totalizer, volume at measurement conditions
conditions
Pulse scaling factor
Meter factor
Monthly data memory 1 ... 14
(Date, Vb, Vm, dVb, dVm, P, T)
Description of the coordinate
Flow rate at base conditions
Calculated flow rate at measurement conditions
Frequency (measurement)
Lower fault limit
Upper fault limit
Maximum value of the flow rate at measurement
conditions
Creeping limit
Time limit for operation below Qm<
Description of the coordinate
Measured value for pressure (absolute pressure)
Lower fault limit
Upper fault limit
Specified value, pressure at base conditions
Default value, pressure
Pressure, binary display
Binary value at 0.5 V
Binary value at 4.5 V
Constant, pressure transmitter base calibration
Constant, pressure transmitter base calibration
Constant, pressure transmitter base calibration
Correction value, pressure transmitter (factor)
Correction value, pressure transmitter (offset)
V
Unit
m3
m3
m3
m3
I/m3
I/m3
·
V
Unit
m3/h
m3/h
Hz
m3/h
m3/h
m3/h
m3/h
s
P
Unit
bara
bara
bara
bara
bara
V
bara
Manual EC 24 · EN05 · 2015-02
Special feature
Special feature
Special feature

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec 21

Table of Contents