SAFETY INSTRUCTIONS
...........................................................................................................................................................................................................

Operating instructions for the installer

Identification:
6
Manufacturer:
Application:
The device EC 21*/EC 24* is equipment for hazardous area.
Assembly/disassembly:
When assembling it is to be made sure that the degree of protection of the case is kept.
A direct exposure to sun must be avoided.
In case of disassembly the signal circuits are to be switched to zero potential and the
corresponding cables are to be removed.
Installation:
If one or more circuits are used, it is to be made sure with the cable selection that the
permissible limiting values according to the EC type approval certificate are not exceeded.
Each Ex signal circuit is to be run in its own cable, which has to be lead through the
appropriate PG cable gland.
A fixed laying of the intrinsically safe cables is obligatory.
The connecting cables are to be provided with core-end sleeves.
...........................................................................................................................................................................................................
Type: EC 21* / EC 24*
II 2 G Ex ib[ib] IIC T3/T4
TÜV 02 ATEX 1970
Temp.= -20°C....+40°C and/or +60°C
Data see EC type approval certificate
Year of construction: 2004
Serial number: xxxx xx
0032
RMG Messtechnik GmbH
Otto – Hahn – Straße 5
D-35510 Butzbach
Manual EC 24 · EN05 · 2015-02