SAFETY DEVICES
Island protection
Safety devices DC side
Safety devices AC side
SYSTEM INFORMATION
User interface
Diagnostics
External communication
MasterBus powering
MasterBus menu languages
MISCELLANEOUS
Cooling
Enclosure
String box option
Transformer option
* The number of menu languages may change without prior notice.
26
CS15TL
Redundant voltage and frequency window
monitoring compatible with national standards
• isolation resistance measurement
• polarity protection (diodes)
• surge protection class III (varistors)
• overload (temperature controlled power
derating)
• voltage / frequency window
• independent AC relays
• Integrated RCD (DC sensitive)
• DC current injection protection
• Ceramic fuse
• Class III surge protection
Multi-language black-on-white graphical LCD
display. Languages: English, Nederlands,
Deutsch, Français, Castellano, Italiano
• 365 days datalogger and real time clock
• 10 years diagnostic memory
A: MasterBus stringbox and transformer
interface with two connectors
B: MasterBus field service interface with two
connectors
C: 2 RS485 connections for DataControl
Professional, maximum 20 inverters, 1000 m
maximum cable length
Yes, when AC and/or DC is available
English, Nederlands, Deutsch, Français,
Castellano, Italiano, Norsk, Svenska, Suomi,
Dansk *
User replaceable fan bracket
Aluminium with powder coating.
Rubber foot stands are part of the enclosure.
Mounting bracket.
IP65 enclosure;
Integrated DC load switch 2x1000V DC /30A;
Integrated string fuses;
Integrated
string
current
Masterbus connection to inverter;
12 (2 x 6) string connections with MC 4 mm
type connectors or glands.
20kW 3-phase transformer in IP54 enclosure
Cooling: natural convection
Transformation losses : max 2%
Weight 200 Kg.
CS20TL
Redundant voltage and frequency window
monitoring
standards
• isolation resistance measurement
• polarity protection (diodes)
• surge protection class III (varistors)
• overload (temperature controlled power
derating)
• voltage / frequency window
• independent AC relays
• Integrated RCD (DC sensitive)
• DC current injection protection
• Ceramic fuse
• Class III surge protection
Multi-language black-on-white graphical LCD
display. Languages: English, Nederlands,
Deutsch, Français, Castellano, Italiano
• 365 days Datalogger and real time clock
• 10 years diagnostic memory
A: MasterBus stringbox interface with two
connectors
B: MasterBus field service interface with two
connectors
C: 2 RS485 connections for DataControl
Professional, maximum 20 inverters, 1000 m
maximum cable length
Yes, when AC and/or DC is available
English, Nederlands, Deutsch, Français,
Castellano, Italiano, Norsk, Svenska, Suomi,
Dansk *
User replaceable fan bracket
Aluminium with powder coating.
Rubber foot stands are part of the enclosure.
Mounting bracket.
IP65 enclosure;
Integrated DC load switch 2x1000V DC /30A;
Integrated string fuses;
monitoring
via
Integrated
Masterbus connection to inverter;
12 (2 x 6) string connections with MC 4 mm
type connectors or glands.
20kW 3-phase transformer in IP54 enclosure
Cooling: natural convection
Transformation losses : max 2%
Weight 200 Kg.
August 2010 / SunMaster CS15TL/CS20TL / EN
compatible
with
national
string
current
monitoring
via

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunmaster cs20tl

Table of Contents