Assemble the COM Express system
2. Plug the fan's 3‐wire cable into the processor fan connector on the CR100 carrier board.
3. Insert the five carrier screws through the back of the CR100 carrier board at the locations 
shown, then tighten the screws to a torque value of 0.3136N∙m (2.78 lbf∙in).
W
ARNING
Install the COM Express assembly into the chassis
1. Prepare a chassis designed to accept a standard FlexATX‐sized board.
2. Remove any I/O shielding included with the chassis, and replace it with the CR100 carrier 
board's I/O shielding from RadiSys.
3. Fit the module and carrier board assembly into the chassis and snap the carrier board's rear 
I/O panel into the I/O shielding.
Note: To avoid electromagnetic interference, ensure that the springs on the I/O shielding are 
in full contact with the CR100 carrier board's rear I/O panel. 
4. Use the screws and standoffs supplied with the chassis to mount the carrier board. Torque 
values vary according to the size and material of the screws used. Check with your chassis 
manufacturer for the recommended torque values of any screws they provide.
18
!
Do not overtighten the screws, or the CR100 carrier board may be damaged.
Carrier screws