Elna International Corps. SA
Xquist
UPPER MAIN SHAFT DISENGAGING
6. Remove the Under cover.
7. Remove the Face cover inside.
8. Remove the Belt cover.
9. Remove the Free arm bottom cover.
10. Loose the 5 screws from the bottom plate base.
11. Remove the Front panel.
12. Disconnect all Front panel connectors.
13. Disconnect all connectors on the left side from the
Relation of the position of the main shaft disengaging
cam and the main shaft-disengaging cam.
1. Provide a clearance of 1,6 mm between the main
2. Loosen adjustment screw 1 and the tree screws 2
3. Move needle-throwing STM installing plate 3 to the
4. Tighten the tree screws 2 to fixe the needle
Note:
When this adjustment is performed, the needle entry
point shifts. Perform again the needle entry
adjustment.
1. Provide a clearance of 1,6 mm between the main
2. Loose the screw 1.
3. Make the top end of the main shaft disengaging
4. Tighten the screw 1.
5. After adjustment, apply grease to the sections
Location of components to be adjusted.
microcomputer circuit board so that you have
access to the Disengaging mechanical system.
HOW TO ADJUST
shaft hand wheel and the main shaft-disengaging
cam. Using a 1.6-mm spacer or the like.
from the needle throwing STM installing plate.
left or right to adjust the distance of 2 mm between
the main shaft-disengaging cam 4 and main shaft
disengaging link 5.
throwing STM installing plate.
After this adjustment, perform the Main shaft
disengaging stopper adjustment.
MAIN SHAFT DISENGAGING STOPPER
shaft hand wheel and the main shaft-disengaging
cam.
stopper comes in contact with the stopper spring.
below.
•
Joint of the main shaft-disengaging cam and
the main shaft hand wheel.
•
Cam section of the main shaft disengaging