Chapter 4 Test & Inspection
5. Fan Calibration And Auto Waveform
Note: Always perform an F-type Fan Calibration after
replacing an F-type fan (Fan5, Fan6, Fan7, FAN8,
FAN10).
Criteria
- If the Fan calibration failure please change
the corresponding fan.
Procedure
-
Plug in power cord and AC on.
- Hold "Down" then press "Power" button.
- Release "Power" and "Down" button when the
Shutter LED flashing yellow.
- After several minutes, the projector will auto-
power on, the fan calibration and auto waveform
is finished.
Note: If the Fan RPM does not meet the RPM
4-8
range, change the corresponding Fan.
(Fan5:3300~3700,Fan6:2500~2700,Fan7:
3300~3700,Fan8:3400~3700,Fan10:3400
~3700)
EK-800U