No Power Troubleshooting - Eiki EK-800U Service Manual

Hide thumbs Also See for EK-800U:
Table of Contents

Advertisement

3-4 No Power Troubleshooting

No Power
Troubleshooting
Is the power cord
connected securely at
the unit and the power
source ?
Yes
Is the power source
providing AC voltage?
Yes
Is the lamp cover securely
in place and properly
fastened?
Yes
Use the voltage test meter
to test the voltage of J2 of
Main Board Pin 1,
13,15=5V?
Change Main Board/Keypad Board
Continue function test and other
troubleshooting once power button
backlight lit
EK-800U
Properly connect power cord at unit
and AC power source
No
Supply AC voltage (100V~240V)
No
Ensure the lamp cover is in it´s correct
closed posistion
No
Pin 1
Pin 20
No
Change Power supply
Chapter 3 Troubleshooting
J2
Pin
Voltage
1
+5V
13
+5V
15
+5V