PROBLEM
doesn't work
Nothing
works
Pump not
running
Pump runs
continuous
VST not
working
Speaker does
not pop up
Water does
not flow
Water too hot
Water will not
heat
Error Codes: XP1 and XP2
CODE
DESCRIPTION
COM
Topside error
bL Er
Device not
detected
O3 Er
P1 Er
Or
P2 Er
Air-locked
P3 Er
pump
CAUSE
No power to
hot tub
Breaker has
tripped
No power to
hot tub
Normal
Pump not
turned on
Speaker
mechanism
broken
Air lock
Closed jets
ACV open
High set
temperature
High ambient
temperature
Thermostat is
set too low
Air open
Dirty filter
Blown fuse
Slide valve
closed
Cover off
Hot tub in
Standby
 Swap topside plug position (C1 to C2)
 Change topside control panel
 Open the access panel to spa pack and reseat
corresponding plug (see page 53)
 Reset GFCI breaker
 Reset Br and LL settings (see page 53)
 Bleed air from system (see page 47)
For HELP, call 727.573.9611
SOLUTION
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Check and reset breaker. If problem
persists, check for loose electrical
connections. Check for Neutral wiring error
at GFCI.
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Hot tub is set for 12x2 filtration. Readjust if
necessary.
Check that the pump (2 or 3) is turned on for
that VST seat (see page 37-40). Check
connections on VST interface box.
Replace speaker.
Bleed air from the system (page 47)
Open all jets by turning counterclockwise
Close air control valves
Turn down set temperature on topside
control panel
Remove the cover from the hot tub
Check and reset to desired temperature
Close air control valve
Check and clean filter
Check and replace fuse
Check and open all valves
Put cover back on hot tub
Press the Standby button and take hot tub
out of Standby
CORRECTIVE ACTION