Speed Detection And Definition - Adash 4900 Vibrio III Manual

Vibration diagnostic tool
Table of Contents

Advertisement

ADASH Ltd.
Adash 4900 – Vibrio III

Speed detection and definition

After switch on of the instrument the Screen No.1 appears and the automatic speed detection begins.
It must be said - obviously. The user can the automatic speed detection switch off in the Menu. The
determination procedure is displayed as running bar in the bottom of screen. The result is also
displayed on the bottom.
When the automatic speed detection is not successful (see Automatic determination of the machine
rotation chapter), the last speed value is loaded from the memory and displayed together with the
message <set>.
Push arrows, it changes the value of speed with the step 250 RPM. When the correct speed ( or the
value near the correct speed) is defined, push Enter button for confirmation.
If no pushbutton is used for approx. 4 seconds, then the displayed value is accepted.
The word <set> is changed to !MAN! then. This word informs all the time the user, that speed is
entered manually.
When you need to set exact value and the 250 RPM step is too much, then use the STROBO item
from the MENU.
If the automatic detection is switch on, this procedure of speed determination runs always when the
Screen No.1 appears. When it is switch off, the immediately the <set> message appears.