SNMPTrapAddress
Regulates or displays IP Trap Addresses and Trap
Levels. Index is a value from 1 to 6. The IP address must
be in the same subnet as the iPBridge, and is the host that
wishes to receive traps. The supported severity levels
required to trigger a trap are: None, All, Warning,
Critical
Default IP address = 1 0.0.0.0
Default level = none
set SNMPTrapAddress [index] [xxx.xxx.xxx.xxx] [None |
All | Warning |Critical]
get SNMPTrapAddress [index]
SNMPTraps
Regulates SNMP traps.If
port, a VLAN ID for that port must be specified. All SNMP
traps are sent with the same VLAN tag.
Default: disabled
set SNMPTraps [enabled |disabled] <[dp1] [VLAN ID]>
get SNMPTraps <[dp1] [VLAN ID]>
SNTP
Controls whether SNTP time server is used.If
enabled on a data port, a VLAN ID for that port must be
specified.
Default: enabled
set SNTP [enabled | disabled] <[dp1] [VLAN ID]>
SaveConfiguration Restart command required
get SNTP <[dp1] [VLAN ID]>
SNTPServer
Controls or displays the main IP address the client uses
to retrieve the SNTP time.
Default: 192.43.244.18
set SNTPServer[xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get SNTPServer
SpeedWrite
Improves the performance of SCSI WRITE commands to
target devices attached to the iPBridge. Specify all to set
the Speed Write state for each currently mapped device
on the iPBridge, or to get a list of the Speed Write states
of all currently mapped devices on the iPBridge.
Default: disabled
set SpeedWrite SCSI [ sb st sl | all] [enabled | disabled]
get SpeedWrite SCSI [ sb st sl | all]
VLAN
is enabled on a data
VLAN
SpeedWriteDefault
Specifies the default
device mappings created manually or using an
operation.
Default: disabled
set SpeedWriteDefault [enabled | disabled]
get SpeedWriteDefault
TailEventLog
Displays new events to the terminal. Type quit then press
ENTER to exit tail mode.
TailEventLog
Temperature
Displays the current internal operating temperature of
this unit in degrees Celsius.
get Temperature
Time
Controls or displays the current time as clocked by the
iPBridge in 24 hour format. Time cannot be set while
SNTP
is enabled.
set Time [HH: MM: SS]
is
get Time
TimeZone
Controls or displays the time zone or an offset from GMT.
Default: EST
set TimeZone [EST | CST | MST | PST] | [+| -] [HH]:[MM]
SaveConfiguration command required
get TimeZone
TraceLog
When enabled, the unit records various system events to
the trace log.
Default: disabled
set TraceLog [enabled | disabled]
get TraceLog
TraceLogFilter
Filters data from specific unit ports when trace logging is
enabled.
Default: all all all
set TraceLogFilter [ SCSI | all ] [ sb | all ] [none | chkcond
| all ]
get TraceLogFilter [ SCSI | all ] [ sb | all ]
SpeedWrite