ATTO Technology iPBridge 2600 Installation And Operation Manual page 42

Hide thumbs Also See for iPBridge 2600:
Table of Contents

Advertisement

iSCSITarget
Creates/deletes an iSCSI target. The target name acts as
a suffix to the standard iPBridge iSCSI-qualified name.
The target name may not exceed 24 characters. A newly-
created target has one LUN, the iPBridge LUN, at LUN
0.
AccessControl
is enabled by default, unless
iSNSLoginControl
is already enabled. If the target
name already exists, this command does nothing. The
default target cannot be deleted.
iSCSITarget [Target Name] <delete>
iSCSITargetNameDisplay
Displays the iSCSI target name.
iSCSITargetNameDisplay
iSCSIWANIPAddress
Sets or displays the IP address reported to an iSCSI
initiator located outside the iPBridge LAN. If this
iPBridge is behind a NAT router, the address must be set
to the external IP address of the router. Setting the
address to 0.0.0.0 causes the iPBridge to be inaccessible
from outside the LAN.
Default: 0.0.0.0
set iSCSIWANIPAddress [dp1 | all] [xxx.xxx.xxx.xxx]
get iSCSIWANIPAddress [dp1 | all]
iSNSLoginControl
Specifies whether the iPBridge delegates its access
control/authorization policy to an iSNS server.
Note
iSNSLoginControl cannot be used with
AccessControl
Default: disabled
set iSNSLoginControl [enabled | disabled]
get iSNSLoginControl
iSNSServer
Specifies the IP address of a valid iSNS server from which
the iPBridge tries iSCSI initiator discovery. Set to
0.0.0.0 to disable iSNS server lookup.
Default: 0.0.0.0
set iSNSServer [xxx.xxx.xxx.xxx]
get iSNSServer
IsReserved
Displays the reservation status of the current iPBridge.
IsReserved
xi
ATTO Technology Inc. iPBridge Installation and Operation Manual
.
MaxOpTemp
Regulates the maximum operating temperature of this
unit in degrees Celsius. Valid entries are between 55 and
70 degrees.
Default: 70
set MaxOpTemp [55 – 70]
SaveConfiguration Restart command required
get MaxOpTemp
MinOpTemp
Regulates the minimum operating temperature of this unit
in degrees Celsius. Valid entries are between 0 and 15
degrees.
Default: 0
set MinOpTemp [0 – 15]
SaveConfiguration Restart command required
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid
entries are between 0 and 15 degrees.
Default: 5
set OpTempWarn [0 – 15]
SaveConfiguration Restart command required
get OpTempWarn
Password
Specifies the password used for all sessions: NDMP,
Telnet, FTP and ExpressNAV. Password is case sensitive,
0 to 32 characters, and cannot contain spaces. An empty
password can be configured by pressing the enter key
when prompted for the new password and new password
confirmation.
Default: Password
set Password
Ping
Sends an ICMP echo request to the specified host.If
VLAN
is enabled, the VLAN ID must be provided.
ping [DPn | MPn |all] [xxx.xxx.xxx.xxx] <count <size>>
ReadOnlyPassword
Specifies a password which allows only read and no
writes. It is case sensitive, 0 to 32 characters, and cannot
contain spaces. An empty password can be configured by
not specifying one.
Default: Password
set ReadOnlyPassword

Advertisement

Table of Contents
loading