Ⅱ.7 DSP1 Setup
1
2
3
4
5
6
Above is the page that appears when clicking [DSP1 Setup] menu.
① Ducking Release Time and Level values are able to setup.
1) DUCKINg Release Time (1ms ~10000ms) setup
- Drag the slide bar using mouse to setup the value you want.
- When clicking [Apply] button, the changed value applies.
2) DUCKINg Level( -12db, -18db, -24db, MUTE ) value.
(Select the Level value you want, then click [Apply] button so it will apply to the device.)
* Slider operation sets up the same as above.
② Setup Limiter Threshold(-4dB ~ 44dB) value.
③ Setup Limiter Attack Time(1ms ~ 20ms) value.
④ Setup Limiter Decay(100ms ~ 2000ms) value.
⑤ Setup HPf frequency(20Hz ~ 400Hz) value. (HPf: HIgH PASS fILER)
⑥ Setup MIX-OUT value.
- LPf Enable: Setup whether to use Low Pass filter or not. (LPf: LOW PASS fILER)
- frequency: Setup frequency value. (20Hz ~ 400Hz)
- Volume: Setup MIX-OUT's volume. (0~100)
⑦ [DSP1 Setup] page will show the help page.
7
MIXINg AMPLIfIER
PMU-240NA/600NA