Goulds Pumps SVT-1SV Technical Manual page 81

E-sv series vertical multi-stage pumps
Table of Contents

Advertisement

Commercial Water
TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING
15SV 1750 RPM
Motor Selection using SF
No. of
Maximum
Impellers
HP draw
Rated HP
15
3.56
5.00
14
3.32
13
3.08
12
2.84
3.00
11
2.61
10
2.37
9
2.13
2.00
8
1.90
7
1.66
1.50
6
1.42
5
1.19
1.00
4
0.95
3
0.71
0.75
2
0.47
0.50
1
0.24
22SV 1750 RPM
Motor Selection using SF
No. of
Maximum
Impellers
HP draw
Rated HP
12
3.58
5.00
11
3.28
10
2.98
3.00
9
2.68
8
2.38
7
2.09
2.00
6
1.79
5
1.49
1.50
4
1.19
3
0.89
0.75
2
0.60
0.50
1
0.30
PAGE 82
Motor Selection 1.0 SF
NEMA
NEMA
Motor Frame Rated HP Motor Frame
ODP
TEFC
ODP
184TC 184TC
184TC 184TC
56C
56C
5.00
184TC 184TC
56C
56C
184TC 184TC
56C
56C
56C
56C
56C
56C
3.00
56C
56C
56C
56C
56C
56C
56C
56C
56C
2.00
56C
56C
56C
56C
56C
56C
1.50
56C
56C
56C
56C
56C
1.00
56C
56C
56C
0.75
56C
56C
56C
56C
0.50
56C
56C
56C
Motor Selection 1.0 SF
NEMA
NEMA
Motor Frame Rated HP Motor Frame
ODP
TEFC
ODP
184TC 184TC
184TC 184TC
5.00
56C
56C
184TC 184TC
56C
56C
56C
56C
56C
56C
3.00
56C
56C
56C
56C
56C
56C
56C
56C
2.00
56C
56C
56C
56C
1.50
56C
56C
56C
56C
56C
1.00
56C
56C
56C
0.75
56C
56C
56C
0.50
56C
L enntech
Shutoff TDH
Shutoff TDH
(Feet)
(psi)
TEFC
263
114
245
106
228
99
56C
210
91
56C
192
83
56C
175
76
56C
158
68
56C
140
61
56C
120
52
56C
103
45
56C
86
37
56C
68
29
56C
51
22
56C
35
15
56C
8
3
Shutoff TDH
Shutoff TDH
(Feet)
(psi)
TEFC
220
95
202
87
56C
183
79
56C
165
71
56C
147
64
56C
129
56
56C
110
48
56C
91
39
56C
74
32
56C
55
24
56C
36
16
56C
19
8
Goulds Pumps
Casing/Sleeve
Shutoff TDH
Pressure Rating
(Bar)
(standard assy.)
7.8
7.3
6.8
6.3
5.7
5.2
4.7
4.2
25 Bar (362 psi)
Class 250 / 300
3.6
3.1
2.6
2.0
1.5
1.0
0.2
Casing/Sleeve
Shutoff TDH
Pressure Rating
(Bar)
(standard assy.)
6.6
6.0
5.5
4.9
4.4
3.8
25 Bar (362 psi)
Class 250 / 300
3.3
2.7
2.2
1.6
1.1
0.6
Pump Flange
Rating
Pump Flange
Rating

Advertisement