Goulds Pumps SVT-1SV Technical Manual page 78

E-sv series vertical multi-stage pumps
Table of Contents

Advertisement

Commercial Water
TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING
92SV 3500 RPM
# of Impellers /
Maximum HP
# reduced
Draw
Diameter
5/1
73.8
5/2
70.3
4
61.9
4/1
58.3
4/2
54.8
3
46.5
3/1
42.9
3/2
39.4
2
31
2/1
27.4
2/2
23.4
1
15.5
1/1
12
1
125SV 3500 RPM
Motor Selection using SF
No. of
Maximum
Impellers
HP draw
Rated HP
5/0C
82.32
75.00
5/5B
67.84
60.00
4/3B
57.35
50.00
3/3A
45.60
40.00
2/0C
34.79
30.00
1/0C
17.40
15.00
Motor HP for use Motor HP for use
with 1.15 SF
with Hydrovar
Motor
(1.0 SF)
75
75
60
60
50
50
40
40
30
30
25
25
20
15
15
Motor Selection 1.0 SF
NEMA
NEMA
Motor Frame Rated HP Motor Frame
ODP
TEFC
ODP
364TSC 365TSC
Contact Factory
324TSC 326TSC
75.00
364TSC 365TSC
324TSC 326TSC
60.00
324TSC 326TSC
286TC 286TC
50.00
324TSC 326TSC
284TC 286TC
40.00
286TC 286TC
215TC 254TC
20.00
254TC 256TC
L enntech
Casing / Sleeve Stages requiring
Shutoff TDH
Shutoff TDH
Pressure rating Thrust Balancing
(Feet)
(Bar)
(Standard Assy.)
732
21.9
707
21.1
605
18.1
580
17.3
556
16.6
454
13.6
429
12.8
25 Bar (362 PSI)
405
12.1
305
9.1
278
8.3
253
7.6
151
4.5
127
3.8
Shutoff TDH
Shutoff TDH
(Feet)
(psi)
TEFC
643
278
555
240
461
200
358
155
263
114
131
57
Goulds Pumps
Pump Flange
Piston
Thrust Piston
Class 250 / 300
Required
1
Class 125 / 150
Casing/Sleeve
Shutoff TDH
Pressure Rating
(Bar)
(standard assy.)
19.2
16.6
13.8
25 Bar (362 psi)
10.7
7.8
3.9
Rating
Pump Flange
Rating
Class 250 / 300
Class 125 / 150
PAGE 79

Advertisement

Table of Contents
loading

Table of Contents