Kongsberg ACS500 Instruction Manual page 89

Acoustic control system, gisma testport system
Table of Contents

Advertisement

3
Remove all cable clips and binding securing the transducer cable to the valve
package.
Disconnect the cable connector from the Subsea Control Unit.
4
Support the transducer to make sure it doesn't fall when the securing bolts are
5
removed.
Remove the bolts securing the transducer to the valve package.
6
Remove the transducer.
7
Lift a new transducer onto the mounting position on the valve package.
8
9
Screw in new bolts of the same type and length as the old ones.
Note
These bolts are not delivered with the transducer as they depend on the thickness
and material of the structure they are mounted on.
10 Tighten the bolts to the torque recommended by the manufacturer.
11 Run the transducer cable to the Subsea Control Unit following the same route as
the original cable.
12 Secure the cable to the frame at the appropriate positions.
13 If necessary, clean the insulators and casing using a stiff brush and water or ethyl
alcohol.
Caution
Do not use trichloroethylene, benzene, methylethylketone etc.
14 Fill the tapered recesses in the front of the insulator with silicone grease.
15 Make the connection and tighten the coupling nut to the torque recommended.
397128/C
Maintenance
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents