Message
Failed
High Current
Low Current
Unknown
Not armed, Force?
Valve already Armed.
Executed. Force?
Cancelled
Timeout-Force?
397128/C
Description
Valve operation may be
executed correctly. Read
back status received is not
as expected.
Warning, Dark green
colour, this specific
operation is OK, but the
solenoid current measured
is above the defined upper
limit. Group B: Status will
be updated with a warning
message.
Warning, Dark green
colour, this specific
operation is OK, but the
solenoid current measured
is below the defined lower
limit. Group B: Status will
be updated with a warning
message.
This valve has not been
operated yet in the
operation window.
Operation of a normal
Valve, when the system
is not in ARM mode.
Warning to operator.
When a Valve is already
active (open) then an
attempt to execute it twice
will give this message.
When Executing a Valve
function and then pressing
the Abort button will give
this message.
When starting up a
command and not receiving
acoustic confirmation from
SCU then we get a Timeout
warning.
Operational procedures
Action
Check details including
current values in More
Status. Try to repeat
operation if possible.
Check sensors and
configuration values.
Check current reading
valve in More status. If
the valve is significantly
outside the defined scope
then check the SCU system.
Check current reading
valve in More status. If
the valve is significantly
outside the defined scope
then check the SCU system.
Continue operation by
pressing the Execute
buttons for 5 seconds.
Continue operation by
pressing the Execute
buttons for 5 seconds.
Proceed with ACU Execute
message by pressing
Execute buttons for 5
seconds. Alternatively,
repeat the complete
function.
59