Operational procedures
In this figure a possible critical error situation has occurred, giving status "VALVE
ERROR". The status in the SCU indicates that the valve package is DISARMED at the
same time as other valves are active. Any attempt to execute the ARM function in this
situation may cause error due to unwanted execution of the active valves in the system.
When trying to execute the DISARM function when ARM sensor is not Active we
get a red background for status "Not armed. Force?" on the valve.
function
DISARM
execution is possible by pressing and tapping the two
buttons.
Execute
Caution
The operator should consider the complete valve situation before forcing any
execution. Using the
menu in order to get a better overview
More Status
over the valve readback situation is recommended.
67