■[F 7] Setting of fine adjustment of display value

This is the function to perform fine adjustment of the displayed pressure manually.
It is adjustable within the range ±5%R.D.
<Operation>
Press the
or
Setting of fine adjustment of display value
Press the
or
Setting of initializing of adjustment
(for initializing adjusted value)
Press the
or
adjustment.
Setting of [F 7] fine adjustment of display value completed
button in function selection mode to display [F 7].
Press the
button.
button to change the set pressure.
Press the
button.
button to select the initializing of
Press the
button to set.
Move on to setting of display resolution.
Press the
button to set.
Move on to setting of adjustment initialize.
Return to function selection mode.