Problems with Network Segmentation Manager
Symptom
The network creation triggered from
vCloud Director fails. A system
message similar to the following is
logged in vCloud Director:
Failed to create port-profile
The network creation triggered from
vCloud Directors fails. A system
message similar to the following is
logged in the vCloud Director:
Template does not exist
The network creation triggered from
vCloud Director fails. A system
message similar to the following is
logged in vCloud Director:
Alias ID not found
The network creation triggered from
vCloud Director fails. A system
message similar to the following is
logged in vCloud Director:
Failed to set port-binding
The network creation triggered from
vCloud Director fails. A system
message similar to the following is
logged in vCloud Director:
Failed to set vlan
Cisco Nexus 1000V Troubleshooting Guide, Release 5.2(1)SV3(1.1)
24-4
Possible Causes
The Cisco Nexus 1000V is unable
to create the port profile required
for the network.
vCloud Director is unable to find
the port profile associated with the
network segment policy associated
with the network.
vCloud Director is unable to
retrieve the port group ID
associated with the port profile
created for the network.
vCloud Director is unable to set the
port binding on the port profile
associated with the network
vCloud Director is unable to set the
access VLAN on the port profile
associated with the network.
Chapter 24
Network Segmentation Manager
Verification and Solution
Check system logs for a port profile failure
message reported by NSM. See the Cisco NX-OS
System Messages Reference for more
information.
Verify if the port profile exists.
1.
show running-config port-profile name
To identify the name of the port profile, you
will need to determine the network segment
policy the network was attempting to use.
You need the information about the
tenant/organization UUID and the type of
network pool the network was being created
from (VXLAN or VLAN) to find the
corresponding network segment policy that
has these values configured. If no network
segment policy is configured with these
values, use the default network segment
policy to identify the name of the port
profile.
Check system logs for a port profile failure
2.
message reported by NSM. See the Cisco
NX-OS System Messages Reference for more
information.
Verify that the Virtual Supervisor Module
(VSM) has an active SVS connection.
show svs connection
When you enter the command, the output must
display
operational status: connected
Check system logs for a port binding failure
message reported by NSM. See the Cisco NX-OS
System Messages Reference for more
information.
Check system logs for a set VLAN failure
message reported by NSM. See the Cisco NX-OS
System Messages Reference for more
information.