Cisco Nexus 1000V Troubleshooting Manual page 185

Switch for vmware vsphere. release 5.2(1)sv3(1.1)
Hide thumbs Also See for Nexus 1000V:
Table of Contents

Advertisement

Chapter 16
ACLs
Command
Step 2
vemcmd show acllog config
Example:
switch# vemcmd show acllog config
switch #
Step 3
logging ip access-list cache max-deny-
flows <num>
Example:
switch# logging ip access-list cache
max-deny- flows <num>
switch #
Troubleshooting a Mismatched Configuration Between a VSM and a VEM
If syslog messages are not being sent and the flow information counters are invalid, the configuration
between a VSM and a VEM might be mismatched.
Modify any mismatched configurations by using the appropriate configuration command. If the problem
persists, enable acllog debugging on both the VSM and the VEM and retry the commands.
BEFORE YOU BEGIN
PROCEDURE
Command
Step 1
show logging ip access-list status
Example:
switch# show logging ip access-list
status
switch #
Step 2
vemcmd show acllog config
Example:
switch# vemcmd show acllog config
switch #
OL-31593-01
Log in to the CLI in EXEC mode.
Description
Verifies ACL logging on the VEM.
Increases maximum flows to the desired value.
Description
Verifies that ACL logging is configured properly.
Verifies ACL logging on the VEM.
Cisco Nexus 1000V Troubleshooting Guide, Release 5.2(1)SV3(1.1)